Coruba are proud distributors of metroseal sm570 00 to iec61111 2009 class 0 metroseal sm570 00 fine ribbed black epdm rubber matting to iec61111 2009 class 0 is a high quality electrical safety matting fully tested to 1 000 volts with regulation standard stamped on reverse of roll at 1000mm intervals.
Electrical insulating rubber mats iec61111 class 0 1000v.
Catu mp 11 11 lv insulating matting is class 0 approved with a maximum safe working voltage of 1000v the electrical insulating mats are used when operating switchboards jointing cables operating live switchgear substations transformers at low voltage lv.
Electrical rubber mats are effective protective gear for the operators as they give safety from electrical shock.
Iec61111 is the standard stipulated for electrical safety flooring standards in the united kingdom europe and middle east too.
Contact t d for prices delivery and technical support for sm570 00 1kv iec61111 class 0 electrical mats.
Iec 61111 class 0 1000v ac rated insulating matting 3 0mm thickness.
Catu electrical insulating matting is specified and tested to iec 61111 category c with working temperatures to 40 c for the following voltages.
Lv insulating matting class 0 safe working voltages 600v 1000v.
The regulation standard is stamped on reverse of all 1000 volt rolls at 1000mm intervals.
Electrical insulation rubber safety floor matting are specific kinds of rubber and non conductive flooring options for operators working on live equipment.
The international standard iec6111 2009 outlines the requirements for rubber insulating matting for electrical purposes and specifies the construction materials thickness width and the testing conditions and results expected to meet the standard.
Iec 61111 electrical insulating switchboard matting specification for insulating matting has replaced bs921 1976 high quality natural rubber insulating matting provides protection to personnel working on switchgear switchboard control panels and transformers.
Maximum safe working voltage of 1 000v.
The international standard iec6111 2009 outlines the requirements for rubber insulating matting for electrical purposes and specifies the construction materials thickness width and the testing conditions and results expected to meet the standard.
The selection table.
Maximum safety working voltage of 1 000v.
Mv hv insulating matting class 3 safe working voltage 3 3kv 6 6kv 11kv 15kv 26 5kv.
Our 1000 volt electrical safety mats conform to regulation iec61111 2009 class 0 with a maximum safe working voltage to 1 000 volts.
Contact t d for prices delivery and technical support for sm570 02 17kv iec61111 class 2 electrical mats.
Class 0 matting protects workers against electrocution according to iec 61111 up to 1 000 volts for lv low voltage applications.